-40%

Quest Model 2700 Precision Impulse Generating Sound Level Meter

$ 52.79

Availability: 100 in stock
  • MPN: 2700
  • Condition: This item is being sold as “For Parts/Untested”.
  • Model: 2700
  • Brand: Quest Technologies
  • All returns accepted: ReturnsNotAccepted

    Description

    Quest Model 2700 Precision Impulse Generating Sound Level Meter
    Description
    This item is being sold as
    “For Parts/Untested”.
    Powered using new 9V batteries. Batteries not included. Used microphone from different unit and was not able to affect readout with various sounds around the shop. Microphone not included. No other accessories. No further testing can be completed. May need calibration. Cosmetically in good condition with some scuffs and scrapes, missing battery cover.
    What’s Included:
    1X Quest Model 2700 Precision Impulse Generating Sound Level Meter
    Does not include any additional cables, parts or accessories other than those explicitly mentioned in the listing.
    Specifications
    Standards
    : Type 2, ANSI S1.4-1983, IEC 651-1979.
    Display
    : 3-1/2 Digit Liquid Crystal Display with an additional Quasi-Analog 60 dB indicator in 2 dB increments. Level display indicates to 0.1 dB resolution. Indicators are included for Battery Check, Hold, and Overload Indication.
    Modes of Operation
    : Measures Sound Pressure Level (SPL) and Maximum Level (MAX). Peak Level (PEAK) and Impulse Level (IMP) can also be measured.
    Minimum Measurement
    : 35dBA. Using Linear Weighting with an Octave Filter Set. The minimum measurement varies depending on the filter frequency selected.
    Maximum Measurement
    : With Model QE4146 or QE7052 Microphone -- 120 dB with 20 dB Crest Factor. (140 dB if measuring a sinusoidal signal.)  Overload indication will occur if upper range is exceeded. Optional microphones for model 1700 will shift the measurement range upward.
    Frequency Weighting Networks
    : A, B, C, and Linear.  When using a filter set, any one of the weightings may be selected.
    Meter Response
    : Slow, Fast, Impulse, and Peak. (The Peak onset time constant is less than 50 microseconds). Peak measurements may be made in either A, B, C, or Linear Weighting.
    Microphones
    : Removable precision 1/2 inch prepolarized condenser (electret) microphone is standard.
    Preamplifier
    : Directly accepts 0.52" microphone, other sizes with proper adapter. Removable preamp will drive up to 100 feet of cable with negligible signal loss. Preamplifier model 056-852. The input impedance is greater than 1 Gohm in parallel with 47 pF.
    Meter Input
    : The input impedance is 1 Megohm in series with 0.1 MFD.  The maximum sinusoidal input voltage is 10V RMS.
    AC Output
    : 3.16 V RMS at full scale (60 dB). (3.8 V RMS maximum) The output impedance is 3.2K ohms. Connected equipment should be at least 10K ohms. The output can be shorted without damaging the meter or changing the meter reading.
    DC Output
    : 0 to 1.00V DC; 60 dB span. Each 0.167V change equals 10 dB. Connected equipment should be at least 10K ohms. The output can be shorted without damaging the meter or changing the meter reading.
    Frequency Range
    : 4 Hz (-3dB) to 50 kHz (-3dB) on linear weighting, meter only. (Subject to microphone limitations.)
    Reference Range
    : 60 to 120 dB Range setting
    Reference SPL
    : 94 dB
    Reference Frequency
    : 1 kHz
    Reference Direction
    : 0°  when using a Free Field Microphone. Sound is arriving from directly in front of the microphone diaphragm.
    Detector
    : True RMS
    Detector Pulse Range
    : 63 dB
    Detector Measuring Range
    : From 0 dB to 40 dB on the painted scale (when measuring a signal with a 20 dB Crest Factor). The extra 20 dB (40 to 60) on top of the measuring range produces the 20 dB Crest Factor capability.
    Primary Indicator Range / Linearity Range
    : 60 dB (The range as indicated by both the dB RANGE switch and the painted 60 dB scale.)  Tested with a sinusoidal signal input.
    Level Linearity
    : Inside the Primary Indicator Range. It is tested on the Reference Range (60 to 120 dB) with a sinusoidal input signal. Tolerance is +/- 1.0 dB.
    Overload Indication
    : OL appearing in the display indicates overload.
    Attenuator Accuracy
    : Referenced from the Reference Range and the Reference SPL (+34 dB on the painted meter scale). Within 0.7 dB from 31.5 Hz to 8 kHz.
    Warm-up Time
    : 30 seconds.
    Accuracy
    : within 0.7 dB at 25°C. Within 1.0 dB over the temperature range of -10°C to +50°C.
    Temperature Range
    : Operation Temperature Range: -10°C to +50°C.  Accuracy over the Operation Temperature is within +/- 0.5 dB. Storage
    Temperature Range (less batteries)
    : -20°C to +60°C. Do not exceed the Storage Temperature Range because possible damage to the unit may result.
    Operating Humidity
    : Over a range of 30 to 90% relative humidity, the accuracy is within +/- 0.5 dB. Do not exceed 95% relative humidity because possible damage to the unit may result.
    Effect of Magnetic Fields
    : A magnetic field of 1 Oersted (80A/m) at 60Hz produces a maximum reading of 40 dB on Linear Weighting.
    Effect of Electrostatic Fields
    : Negligible as long as the protection grid is kept on the microphone.
    Batteries
    : Two 9-volt alkaline batteries (NEDA 1604A) will provide approximately 20 hours of continuous operation. (10 hours with optional filter set.)
    Tripod Mount
    : A threaded insert on back of the meter accepts a standard 1/4-20 tripod mounting screw.
    Size
    : 3.3 x 8.2 x 1.8 inches (84 x 208 x 47mm) not including the height of the preamp.
    Weight
    :  24 oz. (680g) including the preamp and batteries.
    Payment
    Payment via PayPal is expected within 2-days after the winning bid.We only accept bids from US bidders with confirmed PayPal addresses and only accept PayPal as the form of payment.
    Returns
    Returns are not accepted for items listed as For Parts/Not Working
    Please review all photos carefully as they are part of the description per eBay policy.
    Shipping
    ARG-Tech directly only ships to the United States. All international shipments are processed through eBay's Global Shipping Program.
    We take pride in packing items carefully to ensure safe arrival. We ship promptly, usually same or next day after PayPal confirmation.
    We offer combined shipping for customers who purchase more than one item from us at a time. If two items cannot be safely packaged together we reserve the right to ship them separately.
    If you have any special requirements or questions regarding shipping, please contact us before buying.
    Our business hours are Monday – Friday 7AM-4:30PM EST
    Thanks for viewing!